Happily Serving You in the Same Location for Over 58 Years!

Welcome!

Meade - 10" LX200-ACF (f/10) Advanced Coma-Free OTA

Model#: 1010-60-00

Be the first to review this product

Availability: In stock

$1,799.00

FREE SHIPPING (48 States)
OR
Manufactured by: Meade

Details

Meade 10" LX200-ACF Advanced Coma-Free UHTC Optical Tube Assembly

 

Advanced Coma Free Optics (ACF Optics)

Meade Advanced Comafree design is a huge jump over the traditional Schmidt-Cassegrain as far as sharpness of image, flatness of field, and color. Meade Advanced Coma Free Telescopes delivers the same sharp, flat, comafree field from edge to edge as a typical Ritchey-Chretien. The use of the corrector plate in the Meade ACF system creates a closed and protected optical tube, reduces astigmatism and eliminates the diffraction spikes inherent in the traditional RC design. ACF optical system by Meade perform at the same high level as comparable RC systems costing thousands more.

Meade UHTC Ultra-High Transmission Coatings

Increases total light transmission and image brightness by nearly 20% over Meade standard coatings. Objects such as stars, galaxies and nebulae will appear significantly brighter. For more information on Meade UHTC, please, click here.

Primary Mirror Lock

Locks the mirror in place during long exposure astro photography.

Oversize Primary Mirror

Diameters are greater than their listed aperture (e.g., the diameter of the Meade 8" LX200 ACF is actually 8.25"). This additional 1/4" yields a wide, fully illuminated field-of-view.

 

 

Meade LX200 ACF Advanced Coma Free OTA Optical Tube Assembly UHTC Telescopes are the barebones of the high quality Meade LX200-ACF Telescope. Meade LX200 ACF Telescopes bring Advanced Coma imageFree optics within reach of aspiring astronomers everywhere. Now with Meade LX200ACF Advanced Coma-Free Telescope Optical Tube Assemblies you can build your own professional telescope. Meade LX200-ACF Telescopes Advanced Coma-Free OTA Telescopes include many of the field-proven features of the Meade LX200 and Meade LX200GPS Telescopes, such as Primary Mirror Lock, Oversized Primary Mirror, Dust Cover, and Meade's Ultra High Transmission Coatings UHTC. Plus, all Meade Telescopes of the Meade LX 200 ACF Series come with observatory-class optics crafted in the USA, Irvine, California. These Meade LX200ACF Advanced Coma-Free UHTC Telescope Optical Tube Assemblies are excellent components for enthusiasts looking to build their own custom Telescope.

 

 

 


Product Series

LX200-ACF Advanced Coma-Free Optical Tube Assemblies

UHTC

An important optional feature to optimize the performance of your Meade telescope. Image brightness in a telescope is crucially dependent on the reflectivity of the telescope's mirrors and on the transmission of its lenses. Neither of these processes, mirror-reflectivity or lens-transmission, is, however, perfect; light loss occurs in each instance where light is reflected or transmitted. Uncoated glass, for example, reflects about 4% of the light impacting it; in the case of an uncoated lens 4% of the light is lost at entrance to and at exit from the lens, for a total light loss of about 8%.



Early reflecting telescopes of the 1700's and 1800's suffered greatly from mirrors of poor reflectivity- reflection losses of 50% or more were not uncommon. Later, silvered mirrors improved reflectivity, but at high cost and with poor durability. Modern optical coatings have succeeded in reducing mirror-reflection and lens-transmission losses to acceptable levels at reasonable cost.

Meade Standard Coatings: The optical surfaces of all Meade telescopes include high-grade optical coatings fully consistent in quality with the precision of the optical surfaces themselves. These standard-equipment coatings include mirror surfaces of highly purified aluminum, vacuum-deposited at high temperature and overcoated with silicon monoxide (SiO), and correcting lenses coated on both sides for high light transmission with magnesium fluoride (MgF2). Meade standard mirror and lens coatings equal or exceed the reflectivity and transmission, respectively, of virtually any optical coatings currently offered in the commercial telescope industry.

The Meade UHTC Group: Technologies recently developed at the Meade Irvine coatings facility, however, including installation of some of the largest and most advanced vacuum coating instrumentation currently available, have permitted the vacuum-deposition of a series of exotic optical coatings precisely tuned to optimize the visual, photographic, and CCD imaging performance of Meade telescopes. These specialized, and extremely advantageous, coatings are offered here as the Meade Ultra-High Transmission Coatings (UHTC) group, a coatings group available optionally on many Meade telescope models.

In Meade catadioptric, or mirror-lens, telescopes (including the ETX-90EC, ETX-105EC and ETX-125EC; LX10, LX90, and LX200GPS Schmidt-Cassegrains; and LXD55-Series Schmidt-Newtonians) before incoming light is brought to a focus, it passes through, or is reflected by, four optical surfaces: the front surface of the correcting lens, the rear surface of the correcting lens, the primary mirror, and the secondary mirror. Each of these four surfaces results in some loss of light, with the level of loss being dependent on the chemistry of each surface's optical coatings and on the wavelength of light. (Standard aluminum mirror coatings, for example, typically have their highest reflectivity in the yellow region of the visual spectrum, at a wavelength of about 580nm.)

Mirror Coatings: Meade ETX, Schmidt-Cassegrain, and Schmidt-Newtonian telescopes equipped with the Ultra-High Transmission Coatings group include primary and secondary mirrors coated with aluminum enhanced with a complex stack of multi-layer coatings of titanium dioxide (TiO2) and silicon dioxide (SiO2). The thickness of each coating layer precisely controlled to within +/-1% of optimal thickness. The result is a dramatic increase in mirror reflectivity across the entire visible spectrum; at the important hydrogen-alpha wavelength of 656nm. - the predominant wavelength of emission nebulae - reflectivity is increased from 89% to over 97%.

Correcting Lens Coatings: Meade telescopes ordered with the UHTC group include, in addition, an exotic and tightly-controlled series of coatings on both sides of the correcting lens or correcting plate, coatings which include multiple layers of aluminum oxide (Al2O3), titanium dioxide (TiO2), and magnesium fluoride (MgF2). Per-surface light transmission of the correcting lens is thereby increased at the yellow wavelength of 580nm., for example, to 99.8%, versus a per-surface transmission of 98.7% for the standard coating.

The importance of the UHTC group becomes apparent when comparing total telescope light transmission, or throughput, caused by the multiplier, or compounding, effect of the four optical surfaces. With each optical surface contributing significantly to telescope light throughput, the effect of all four surfaces combined is indeed dramatic, as demonstrated by the graphs on the facing page, as well as by the table of the brightest nebular emission lines. At the H-alpha wavelength of 656nm., total transmission increases from 77% to 93%, an increase of 93/77 or 21% at all three nitrogen-III and sulfur-II wavelengths of 655nm. and 673nm.- prominent lines in certain galactic nuclei and in supernova remnanats such as the Crab Nebula- transmission increases by 21%; ; at the helium wavelengths of 588nm. and 469nm. - strong emission lines in hot planetary nebulae - total telescope transmission increases by 18% and 19%, respectively; at the two nitrogen II lines of 655nm. and 658nm. and at the sulfur II line of 673nm., transmission is increased by 21%. Averaged over the entire visible spectrum (450nm. to 700nm.), total light transmission to the telescope focus increases by about 20%.

Observing with the UHTC: Meade ETX, Schmidt-Cassegrain, and Schmidt-Newtonian telescopes equipped with the UHTC present dramatically enhanced detail on the full range of celestial objects - from emission and planetary nebulae such as M8, M20, and M57 to star clusters and galaxies such as M3, M13, and M101. Observations of the Moon and planets, since they are observed in reflected (white) sunlight, benefit in image brightness from the full spectrum of increased transmission. The overall effect of the UHTC is, as it relates to image brightness, to increase the telescope's effective aperture. Image brightness (i.e., the ability to see faint detail) of the Meade 10" LX200GPS is, for example, effectively increased by about one full inch of aperture.

Emission Line Wavelength (nm.) Transmission: Standard Coatings (%) Transmission: UHTC Group (%) Increase*
Hydrogen-alpha (Ha) 656 76.9 93.1 21%
Hydrogen-beta (Hb) 486 75.3 85.8 14%
Oxygen III 496 76.5 85.4 12%
Oxygen III 501 77 85.4 11%
Helium II 496 72.5 86.1 19%
Helium I 588 79.5 93.5 18%
Nitrogen II 655 77 93.2 21%
Nitrogen II 658 76.7 92.8 21%
Sulfer II 673 75.7 91.8 21%


* The % increase is obtained by dividing the UHTC-transmission (column 4) by the standard coatings transmission (column 3).

Effects on CCD Imaging: While the human eye loses sensitivity to light beyond wavelengths of about 700nm., CCD imaging chips remain sensitive to about 750nm. and longer, wavelengths at which the reflectivity of an aluminum coating is near its lowpoint. Importantly, however, the UHTC's total light transmission at 750nm. is 83%, vs. 72% for standard coatings, an increase of 83/72, or 15%.

Additional Information

Name Meade - 10" LX200-ACF (f/10) Advanced Coma-Free OTA
Manufacturer Meade
Model 1010-60-00
Aperture 254mm (10")
Focal Length 2500mm
Focal Ratio f/10
Mount None
Optical Coatings Ultra-High Transmission Coatings (UHTC)
Optical Design Advanced Coma-Free (ACF) with UHTC
Primary Mirror Progressive tension mirror lock -Pyrex glass